Page 7-9 Reader Configuration
10. Configure the Start and Stop bits for the Wiegand transmission. Click Next.
11. Data Map is complete. Click Finish.
Field Description
STX Bit
Adds a bit at the start of the data transmission
Options are: None, Fixed Bit-Logic 0, Fixed Bit-Logic 1, Even Parity, Odd Parity
Bit Number STX computed from bit 0 to Bit Number.
ETX Bit
Adds a bit at the end of the data transmission
Options are: None, Fixed Bit-Logic 0, Fixed Bit-Logic 1, Even Parity, Odd Parity
Bit Number ETX computed from bit number to end of data.